Complete static and dynamic electrical tests can be performed on any general purpose small signal or power relay with the model RTC225 relay tester. All standard DC group A parametric measurements can be made as well as critical contact timing. A miss-stick life cycling function is built in as well.
The standard DC coil drive powers coils up to 800mA and 150Volts. An optional AC coil driver will handle coils to 270VAC.
An internal 50mA DC source supplies the load for contact voltage drop measurement. Using an external power supply extends this range to 1 ampere. Optional load switching provides at least 10 amperes to each switching contact.

Tests
Pull-in/Drop Out Voltage (ramp or step)
Pull-in/Drop Out Current (ramp or step)
Operate / Release Time
Contact Bounce Time
Contact Resistance / Voltage Drop
Contact Stabilization Time
Coil Resistance
Coil Current
Induced Coil EMF
Time Delay Operate / Release
Dielectric Withstanding Voltage1
Insulation Resistance1

Programmable
Test Conditions
Coil Voltage
Coil Current
Coil Ramp Rat / Step Rate
Coil Current Soak Time
Contact Configuration (up to 4PDT)
Contact Load Level
Contact Load Current1
Contact Settling Time
Dielectric Test Voltage1
Dielectric Test Dwell Time

Measurement Ranges2
Voltage: 0 to 80.00VDC
Coil Current: 0 to 800.0 MADC
Oper. / Rel.Time: 0 to 163.83 MS
Bounce Time: 0 to 163.83 MS
Time Delay: 0 to 65.534 S
Contact Volta Coil ge Drop: 0 to 80.00 MV
Contact Resistance3: 0 to 3.000 Ohms

1. Parameters supported by optional expansion modules.
2.Accuracy on all measurements is ±0.5% of measured value ±1 LSB.
3.The internal contact load is 10 MA/30 MV open circuit